Products

GRMS » Wired GRMS Range » Dimmers »


DALI/DMX Controller for 64 Ballasts

Product Number: DALI-DMX-64


  •  The unit EMDC-64M is designed to control DALI electronic ballasts and DMX receivers from the DynamicPro system.
  •  EMDC-64M enables control of up to 64 independent electronic ballasts
  •  DALI (Digital Addressable Lighting Interface) for fluorescent lamps, LEDs and other light sources.
  •  EMDC-64M also enables connection of up to 64 DMX receivers (Digital MultipleX).
  •  Control from DynamicPro BUS System via EBM BUS.
  •  DIP switches on the front panel to select the control interface (DALI/DMX).
  •  Addressing of DALI ballast units can be done via the central unit and iDM3 software or via MINI USB on the front panel of the EMDC-64M and DALI Configurator software.
  •  The required functionality is set in user project in iDM3 software.
  •  The unit EMDC-64M is powered from the mains voltage 230 V AC.
  •  DALI BUS power supply is 16 V/250 mA via an EMDC-64M unit.
  •  The system BUS EBM is galvanically separated from the BUSes DALI/DMX. Terminals for connecting the DALI BUS are equipped with short circuit and surge protection.
  •  It is possible to connect up to 8 EMDC-64M units to one EBM BUS.
  •  If this concerns the last unit on a system BUS EBM, it is necessary to terminate the wire with a resistor with nominal resistance of 120 Ω. The resistor is inside the unit, termination   is made by shorting neighboring terminals TERM and EBM+.
  •  The BUS DMX must be terminated at its end by a resistor with nominal resistive value 120 Ω. The resistor for DMX BUS termination is on the side of the EMDC- 64M inside the     unit, termination is performed by shorting adjacent terminals TERM and A.
  •  Updating the firmware of the EMDC-64M can be done through the central unit adn software iDM3 or via MINI USB on the front panel and EMDC-64M Flasher software. Updating   through MINI USB must be done while system BUS EBM is disconnected.
  •  When configuring DALI addresses two types are necessary to distinguished:
    ​- MASTER – this group includes sensors and detectors and one DALI branch can connect up to 4 DALI MASTER units
  •  lighting intensity sensor DLS3-1
  •  motion detector DMD3-1
    – SLAVE – electronic lighting ballast
  •  EMDC-64M in 3-MODULE design is designed for mounting in a control panel on a DIN rail EN60715.

Order Inquiry


Description

  •  The unit EMDC-64M is designed to control DALI electronic ballasts and DMX receivers from the DynamicPro system.
  •  EMDC-64M enables control of up to 64 independent electronic ballasts
  •  DALI (Digital Addressable Lighting Interface) for fluorescent lamps, LEDs and other light sources.
  •  EMDC-64M also enables connection of up to 64 DMX receivers (Digital MultipleX).
  •  Control from DynamicPro BUS System via EBM BUS.
  •  DIP switches on the front panel to select the control interface (DALI/DMX).
  •  Addressing of DALI ballast units can be done via the central unit and iDM3 software or via MINI USB on the front panel of the EMDC-64M and DALI Configurator software.
  •  The required functionality is set in user project in iDM3 software.
  •  The unit EMDC-64M is powered from the mains voltage 230 V AC.
  •  DALI BUS power supply is 16 V/250 mA via an EMDC-64M unit.
  •  The system BUS EBM is galvanically separated from the BUSes DALI/DMX. Terminals for connecting the DALI BUS are equipped with short circuit and surge protection.
  •  It is possible to connect up to 8 EMDC-64M units to one EBM BUS.
  •  If this concerns the last unit on a system BUS EBM, it is necessary to terminate the wire with a resistor with nominal resistance of 120 Ω. The resistor is inside the unit, termination   is made by shorting neighboring terminals TERM and EBM+.
  •  The BUS DMX must be terminated at its end by a resistor with nominal resistive value 120 Ω. The resistor for DMX BUS termination is on the side of the EMDC- 64M inside the     unit, termination is performed by shorting adjacent terminals TERM and A.
  •  Updating the firmware of the EMDC-64M can be done through the central unit adn software iDM3 or via MINI USB on the front panel and EMDC-64M Flasher software. Updating   through MINI USB must be done while system BUS EBM is disconnected.
  •  When configuring DALI addresses two types are necessary to distinguished:
    ​- MASTER – this group includes sensors and detectors and one DALI branch can connect up to 4 DALI MASTER units
  •  lighting intensity sensor DLS3-1
  •  motion detector DMD3-1
    – SLAVE – electronic lighting ballast
  •  EMDC-64M in 3-MODULE design is designed for mounting in a control panel on a DIN rail EN60715.

Specification

  • DynamicPro BUS/EBM: EBM
  • DALI/DMX BUS: 64 channels / 64 channels
  • Supply voltage: AC 230 V (50/60 Hz), max. 100 mA
  • Housing: 3-MODULE
  • Dimensions: 90 x 52 x 65 mm

Downloads

Contact Us

  • Address:
    CANADA
    : Unit 157 – 99 Scurfield Boulevard, Winnipeg, MB, R3Y 1Y1 , CANADA.
    UAE: LIU No.11 Dubai Silicon Oasis P.O. Box 293640 Dubai United Arab Emirates
  • Email us:
    info@dynamicpro.ca 
    info@ateis.ae
  • Call:
    Canada Office: +1 (204) 306 5173

    UAE Office: +971 (4) 3262730

 

LEADING INNOVATION
IN LIFE SAFETY
DynamicPro is a Canadian company specializing in providing integrated
technologies in life safety and advanced building management solutions.



Our Address

-CANADA Address: Unit 157 - 99 Scurfield Boulevard, Winnipeg, MB, R3Y 1Y1 , CANADA.
-UAE Address: LIU No.11 Dubai Silicon Oasis P.O. Box 293640 Dubai United Arab Emirates

Sun-Thurs: 8:30am - 6:30pm

info@dynamicpro.ca / info@ateis.ae

+1 (204) 306 5173 / +971 (4) 3262730

Copyright 2022 © Dynamicpro